CVE-2026-103406
Session Smart Conductor automated provisioning command injection lets unauthenticated attackers run code (CVE-2026-103406)
Juniper Session Smart Conductor has a critical command injection flaw in AutomatedProvisioner that lets an unauthenticated attacker execute commands as root. It is exploited in the wild. Patch to 7.0.5, 7.1.7 or 7.2.3.
What happened
Juniper Networks Session Smart Conductor has an OS command injection flaw (CWE-78) in the AutomatedProvisioner. A remote attacker who can reach the service can supply a specially crafted salt minion ID and cause arbitrary commands to execute as root. No valid credentials or user interaction are needed, and the CVSS 3.1 vector is AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, giving a score of 9.8 critical. This means an attacker on the network can fully compromise confidentiality, integrity and availability of the affected system.
This is not theoretical. CISA's Known Exploited Vulnerabilities catalog lists CVE-2026-103406, and CISA's SSVC assessment marks exploitation as active. ENISA EUVD records exploitation since 2026-11-25. The CISA KEV entry was added on 2026-11-25; no due date or required action is listed.
Who is affected
Affected versions are Session Smart Conductor before 7.0.5, 7.1.0 through versions before 7.1.7, and 7.2.0 through versions before 7.2.3. If you run any of these, you are in scope.
What to do now
- Patch to a fixed release. Juniper has published fixed versions: 7.0.5, 7.1.7 and 7.2.3. Choose the release that corresponds to your current branch.
- Because exploitation is active, treat this as an emergency change. Prioritise internet-facing and other reachable conductors first.
- If you cannot patch immediately, restrict network access to the conductor so only trusted management hosts can reach it. The CVE record does not document a workaround; review the Juniper bulletin linked on this page for any additional containment advice.
- Review the Juniper security bulletin and CISA KEV entry linked on this page for any additional context.
How to detect it
The CVE record describes command execution through a crafted salt minion ID during automated provisioning. Log sources that cover provisioning events, and process execution under the conductor's service account, may show unexpected root activity or unusual requests. No vendor-published indicators of compromise are listed in the sources used for this page.
Beyond the patch
Because this vulnerability is already being exploited and is reachable over the network without credentials, the first priorities are detection and response. Our Managed Detection & Response and Incident Response Retainer provide the detection and response capacity for this kind of active threat. Virtual CISO Services can help you find internet-exposed Session Smart Conductor deployments before an attacker does.
Affected and fixed versions
| Product | Affected | Fixed in |
|---|---|---|
| Session Smart Conductor | – < 7.0.5 7.1.0 – < 7.1.7 7.2.0 – < 7.2.3 | 7.0.5 7.1.7 7.2.3 |